21 CFR Part 211 · Current Good Manufacturing Practice for Finished Pharmaceuticals

§ 211.84 Testing and approval or rejection of components, drug product containers, and closures

Subpart E - Control of Components and Drug Product Containers and Closures Official text on eCFR Amendment history

(a) Each lot of components, drug product containers, and closures shall be withheld from use until the lot has been sampled, tested, or examined, as appropriate, and released for use by the quality control unit.

(b) Representative samples of each shipment of each lot shall be collected for testing or examination. The number of containers to be sampled, and the amount of material to be taken from each container, shall be based upon appropriate criteria such as statistical criteria for component variability, confidence levels, and degree of precision desired, the past quality history of the supplier, and the quantity needed for analysis and reserve where required by § 211.170 .

(c) Samples shall be collected in accordance with the following procedures:

(1) The containers of components selected shall be cleaned when necessary in a manner to prevent introduction of contaminants into the component.

(2) The containers shall be opened, sampled, and resealed in a manner designed to prevent contamination of their contents and contamination of other components, drug product containers, or closures.

(3) Sterile equipment and aseptic sampling techniques shall be used when necessary.

(4) If it is necessary to sample a component from the top, middle, and bottom of its container, such sample subdivisions shall not be composited for testing.

(5) Sample containers shall be identified so that the following information can be determined: name of the material sampled, the lot number, the container from which the sample was taken, the date on which the sample was taken, and the name of the person who collected the sample.

(6) Containers from which samples have been taken shall be marked to show that samples have been removed from them.

(d) Samples shall be examined and tested as follows:

(1) At least one test shall be conducted to verify the identity of each component of a drug product. Specific identity tests, if they exist, shall be used.

(2) Each component shall be tested for conformity with all appropriate written specifications for purity, strength, and quality. In lieu of such testing by the manufacturer, a report of analysis may be accepted from the supplier of a component, provided that at least one specific identity test is conducted on such component by the manufacturer, and provided that the manufacturer establishes the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

(3) Containers and closures shall be tested for conformity with all appropriate written specifications. In lieu of such testing by the manufacturer, a certificate of testing may be accepted from the supplier, provided that at least a visual identification is conducted on such containers/closures by the manufacturer and provided that the manufacturer establishes the reliability of the supplier's test results through appropriate validation of the supplier's test results at appropriate intervals.

(4) When appropriate, components shall be microscopically examined.

(5) Each lot of a component, drug product container, or closure that is liable to contamination with filth, insect infestation, or other extraneous adulterant shall be examined against established specifications for such contamination.

(6) Each lot of a component, drug product container, or closure with potential for microbiological contamination that is objectionable in view of its intended use shall be subjected to microbiological tests before use.

(e) Any lot of components, drug product containers, or closures that meets the appropriate written specifications of identity, strength, quality, and purity and related tests under paragraph (d) of this section may be approved and released for use. Any lot of such material that does not meet such specifications shall be rejected.

Independent copy, not an official legal edition. 21 CFR is a U.S. Government work in the public domain; this text comes from the eCFR and the annual CFR edition, and may lag recent amendments. The authoritative version is on ecfr.gov. Compliome is not affiliated with or endorsed by FDA. Not legal advice.

What FDA inspectors cite under § 211.84

Form FDA 483 observations citing this section, fiscal years 2009–2026 (Drugs).

  • Reports of Analysis (Components) 432
  • Identity Testing of Each Component 255
  • Establish reliability of supplier's C of A 196
  • Components withheld from use pending release 150
  • Testing Each Component for Conformity with Specs 118
  • Component identity verification 111

Warning letters citing § 211.84

390 FDA warning letters since 2017 cite this section ; the most recent:

FDA guidance that cites § 211.84

and 15 more.

Amendment history

Federal Register documents that created or amended this section.